440 volt inverter voltage limit

inverter setting values. 440 volt inverter OUTPUT VOLTAGE LIMIT OPTIONS OF 440 VOLT INVERTER. 0: DISABLED. 1:EFFECTIVE THE MOTORS FLUX FALLS AUTOMATICALLY  WHEN THE OUTPUT VOLTAGES REACHES SATURATION STATUS. INVERTER/MOTOR CURRENT. NOTE:  OUTPUT VOLTAGE LIMIT ACTION IS DISABLED , IF THE OUTPUT VOLTAGE REACHES SATURATION STATUS, THE OUTPUT CURRENT HAS NO CHANGE BUT THE TORQUE … Read more

440 volt inverter fault setting

EXTERIOR FAULT ,(SETTING,20-2 F)   This is to set how to output the warning to exterior when the exterior equipment is at fault or in a abnormal status and the inverter stops. as the input condition for exterior fault , it can choose the inverter,s action when the exterior is input . the following setting … Read more

440 volt inverter terminals table

440 VOLT INVERTER,S TERMINALS TABLE No Name Description Setting range Factory setting Change During Option Control methods v/f v/f with pg Open loop vector Flux vector H4-03 Bias (terminal 21) To set the voltage level deviation of multi function analog value output 1 and make the output characteristic to be parallel to the value of … Read more

440 volt inverter analog signal level setting table

  No Name description Setting range Factory setting Change during operation Control methods v/f v/f with pg Open loop vector Flux vector H4-07 Analog output signal level selection The set signal output level of multi function analog value 1.2 (terminal 21,23)0:0~+10v 1:0~+_10v output note of setting : this signal level setting is suitable for multi … Read more

440 volt inverter

Monitor selection after power up when the inverter is started, please set the item need to display 1:frequency command 2:frequency command. 3:output current 4:the displayed item set by o1-01. note: when the inverter is started, to display the frequency command in data displaying part (when factory setting is available) when the inverteris started, the display … Read more