WINNER,S OPERATION SELECTION AT OVER SPEED

OPERATION SELECTION AT OVER SPEED/ DEVIATION . winner inverter set the stop method when over speed occurs.0:deceleration to stop using deceleration time 1 (c 1-0 2). 1: coast to stop. 2: emergency stops using the emergency stop time ( c 1-0 9). 3:continue operation it dose not need to be set normally to protect the … Read more

winner inverter acceleration time setting

Win- va /vc,s deceleration / acceleration time has 4 options , to switch between these time option , please set deceleration / acceleration time option 1 ,2  at multi function input . setting value 7 = acceleration / deceleration time selection 1 . setting value 1 a =  acceleration / deceleration time selection 2 . … Read more

WINNER INVERTER,S UP / DOWN COMMAND SETTING 10, 11.

It is the function to control the inverter,s output frequency through the control terminal,s on/off . when using this function please make sure to set the 2 multi function input up/down command .if only to set single multi function input the fault ope 03 will occur .besides in the occasion where acceleration /deceleration stop was … Read more

winner inverter fault setting

In the occasion where up/down was set multi step peed command 1~8 will be all non effective . the dwell output frequency when up/down is on will be memorized by the value of d4-01 (dwelling function option of frequency command) the setting value is 1 . the value will be recorded after the power is … Read more

winner pid control and operate motor

TO CANCEL PID CONTROL off = pid control is enabled . on = pid control is disabled ( normal control of inverter ) with this setting ,the multi – function input switches between pid control and normal inverter control . this function can be used to perform trial operation or jog operation with normal inverter … Read more

winner dc braking command

Maximum output frequency / exterior search command 1 (setting , 61 ). off = normal action . on = start speed search from maximum output frequency . Setting frequency / exterior search command 2 (setting , 62) . off = normal action . on = start speed search  from the et frequency ( the command … Read more

winner inverter settings

BASE TERMINAL 13 . The input is the frequency at 0,v , it is set in unit of % with max . output frequency taken as 100% please referee to h3- 11 . SIGNAL LEVEL SELECTION TERMINAL 16 . Please see the signal level of multi functional analog input 0:0~ + 10 volt [11 bit +polarity positive … Read more