When terminal 14 is used as frequency command  please h3-09 (frequency command (current ) terminal 14 function selection ) to be if otherwise if you use this function fault (o p e 03)  will occur . when h3 -09 (frequency command ( current ) terminal 14 function selection ) is set as if but multi … Read more

WINNER INVERTER,S UP / DOWN COMMAND SETTING 10, 11.

It is the function to control the inverter,s output frequency through the control terminal,s on/off . when using this function please make sure to set the 2 multi function input up/down command .if only to set single multi function input the fault ope 03 will occur .besides in the occasion where acceleration /deceleration stop was … Read more

winner inverter fault setting

In the occasion where up/down was set multi step peed command 1~8 will be all non effective . the dwell output frequency when up/down is on will be memorized by the value of d4-01 (dwelling function option of frequency command) the setting value is 1 . the value will be recorded after the power is … Read more

winner pid control and operate motor

TO CANCEL PID CONTROL off = pid control is enabled . on = pid control is disabled ( normal control of inverter ) with this setting ,the multi – function input switches between pid control and normal inverter control . this function can be used to perform trial operation or jog operation with normal inverter … Read more

440 volt inverter fault setting

EXTERIOR FAULT ,(SETTING,20-2 F)   This is to set how to output the warning to exterior when the exterior equipment is at fault or in a abnormal status and the inverter stops. as the input condition for exterior fault , it can choose the inverter,s action when the exterior is input . the following setting … Read more

winner dc braking command

Maximum output frequency / exterior search command 1 (setting , 61 ). off = normal action . on = start speed search from maximum output frequency . Setting frequency / exterior search command 2 (setting , 62) . off = normal action . on = start speed search  from the et frequency ( the command … Read more

winner inverter constant function

h2-01,multi function input (terminal 9-10 ) is multi function contact output terminal 9-10,s function selection (contact ). h2-02,multi function input (terminal 25-27) is the function selection of multi function output 1 terminal 25 (open  circuit collector) h2-03 multi function input (terminal 26-27) is the function selection of multi function output 2 terminal 26 function output … Read more

winner inverter settings

BASE TERMINAL 13 . The input is the frequency at 0,v , it is set in unit of % with max . output frequency taken as 100% please referee to h3- 11 . SIGNAL LEVEL SELECTION TERMINAL 16 . Please see the signal level of multi functional analog input 0:0~ + 10 volt [11 bit +polarity positive … Read more

solar max inverter

SOLAR MAX INVERTER,S SPECIFICATIONS model                                                1.2K 2.4K Input voltage                                                             230 VAC Voltage  range                          170-280 VAC(narrow mode)                              90-280vac(wide mode) OUTPUT Voltage regulation (BATT.MODE)                         +/-10% Transfer time                                         20 ms typical Wave form                                       Simulated since wave BATTERY Battery voltage                           12vdc                       24vdc Floating charge voltage                13.5vdc+_0.5 VDC 27.0vdc+_0.5vdc Maximum … Read more

winner frequency selection

  Terminal s/n Content Specification Ta 1 1 Power supply for  encoder Dc + 12v (+-5)max .20ma 2 Dc o v ( grounding terminal for power supply) 3 A phase pulse input terminal H : +8v ~12v L:>+ 1v (max, response  frequency 30 Hz) 4 A phase pulse input terminal 5 B phase input terminal … Read more