electric inverter frequency

electric inverter frequency reference when the multi function inputs jog frequency reference selection f jog command and r jog command are on.the electric inverter frequency reference default value and set value will change when 0 1-0 3 is changed, for example if preset reference 1 is set to 6.00 Hz and 01-03 is changed to … Read more

electric inverter torque reference

TORQUE REFERENCE DELAY TIME . the primary delay time constant of  torque command filter is set in unit of    m r s to adjust the electric inverter torque reference  time constant of the primary delay filmier . to adjust the noise of the torque control signal or the responsive nests with the host controller … Read more

frequency speed and voltage of inverter

  set only  to fine adjust v/f for the output range when using flux vector control of frequency speed and voltage of inverter .normally this setting range and factory setting will be cut by 50%  for the inverter of 200v class . to set the constant e 1-0 4 ~e 1-10 when e 1-0 3 =”f” … Read more

motor system

motor system in inverter MOTOR 2 LINE TO LINE RESISTANCE . To set the motor,s line to line resistance in unit of ohm . note: the factory setting depends on the capacity of the inverter . please set the motor,s line to line resistance u v v – w w u  normally you need to … Read more

digital systems

DIGITAL SYSTEMS INPUT OPTION OF INVERTER. To set the input method of digital command card . 0: bcd . 1% 1: bcdo . 1% 2: bcdo. 01% unit 3: bcd 1Hz unit. 4:bcdo . 1 Hz unit 5:bcdo. 1Hz unit . 6: bcd special setting (5-digital input) . 7: binary system. note: when using a … Read more

working of inverter

FUNCTION TABLE OF MULTI FUNCTION  INPUT (H1). 0: 3 line system program control (forward / reverse command ). 1: local / remote selection (on operator off parameter setting). 2: selection / inverter selection (on is optional ). 3: when h3 – 05 ( multi functional multi speed command 1 analog input function selection ) is … Read more

inverter dc to ac

Finding the Best Inverter Dc to Ac inverter dc to ac Inverter Dc to Ac – Overview Generally, as soon as an inverter is in over-power mode, it simply suggests that it’s going to sacrifice the surplus power. There are not any inverters used inside the computer system. The smallest inverters are somewhat more portable … Read more

inverter panel

PANEL/REMOTE SETTING VALUE 1. OFF:To select frequency command (b1-01) and operation command (b1-02). ON : Set frequency command/operation command by digital operator . To switch the input method between frequency command and operation command . To switch only at the stop of inverter . Once  the function was set digital keyboard operation method selection key … Read more

winner pid control and operate motor

TO CANCEL PID CONTROL off = pid control is enabled . on = pid control is disabled ( normal control of inverter ) with this setting ,the multi – function input switches between pid control and normal inverter control . this function can be used to perform trial operation or jog operation with normal inverter … Read more

440 volt inverter fault setting

EXTERIOR FAULT ,(SETTING,20-2 F)   This is to set how to output the warning to exterior when the exterior equipment is at fault or in a abnormal status and the inverter stops. as the input condition for exterior fault , it can choose the inverter,s action when the exterior is input . the following setting … Read more