torque converter

TORQUE CONVERTER / INVERTER. use for control starting load when this function is used the start torque converter compensation is set by command mechanical friction load , for the elevator.the setting of torque converter start torque rising time is in unit of Mr s(note )filter delay is disabled when the setting is between 0~4 ms NOTE: … Read more

electric inverter frequency

electric inverter frequency reference when the multi function inputs jog frequency reference selection f jog command and r jog command are on.the electric inverter frequency reference default value and set value will change when 0 1-0 3 is changed, for example if preset reference 1 is set to 6.00 Hz and 01-03 is changed to … Read more

motor system

motor system in inverter MOTOR 2 LINE TO LINE RESISTANCE . To set the motor,s line to line resistance in unit of ohm . note: the factory setting depends on the capacity of the inverter . please set the motor,s line to line resistance u v v – w w u  normally you need to … Read more

winner pid control and operate motor

TO CANCEL PID CONTROL off = pid control is enabled . on = pid control is disabled ( normal control of inverter ) with this setting ,the multi – function input switches between pid control and normal inverter control . this function can be used to perform trial operation or jog operation with normal inverter … Read more

440 volt inverter fault setting

EXTERIOR FAULT ,(SETTING,20-2 F)   This is to set how to output the warning to exterior when the exterior equipment is at fault or in a abnormal status and the inverter stops. as the input condition for exterior fault , it can choose the inverter,s action when the exterior is input . the following setting … Read more

solar max inverter

SOLAR MAX INVERTER,S SPECIFICATIONS model                                                1.2K 2.4K Input voltage                                                             230 VAC Voltage  range                          170-280 VAC(narrow mode)                              90-280vac(wide mode) OUTPUT Voltage regulation (BATT.MODE)                         +/-10% Transfer time                                         20 ms typical Wave form                                       Simulated since wave BATTERY Battery voltage                           12vdc                       24vdc Floating charge voltage                13.5vdc+_0.5 VDC 27.0vdc+_0.5vdc Maximum … Read more

winner frequency selection

  Terminal s/n Content Specification Ta 1 1 Power supply for  encoder Dc + 12v (+-5)max .20ma 2 Dc o v ( grounding terminal for power supply) 3 A phase pulse input terminal H : +8v ~12v L:>+ 1v (max, response  frequency 30 Hz) 4 A phase pulse input terminal 5 B phase input terminal … Read more

solar inverter bellco

NOTE : Before installation  please inspect  the unit  be sure that nothing inside the package is damaged. Installation note before installation,please inspect the unit. be sure that nothing inside the package is damaged. Mountain the unit The unit only can be mounted vertically to a wall surface. please follow below steps: 1. Turn off the … Read more

winner inverter

Signal level selection of multi function analogy terminal  14 0: 0~+ 10 volt please make sure to cut off the over line 1 1: 0 ~+_10 volt please make sure to cut off the over line 1 2: 4 ~ +_20 ma  ( 10 bit input ) frequency (current ) it is effective when b1 _ … Read more

440 VOLT INVERTER,S (H3-01,11,12) CONSTANT FUNCTIONS

NO Name                         Description Setting range Factory setting Bias (terminal 14) The command value of each function when 0 v (4 ma)is input , the unit is % -100~ +100 0.0 H3-11 Note : as the adjustment constant of analog input it is classified into 3 types gain deviation ( to be set individually for … Read more