Signal level selection of multi function analogy terminal 14
0: 0~+ 10 volt please make sure to cut off the over line 1
1: 0 ~+_10 volt please make sure to cut off the over line 1
2: 4 ~ +_20 ma ( 10 bit input )
frequency (current ) it is effective when b1 _ 01 (frequency command selection ) is set to be 1
signal level to set frequency command (current )signal .
Note of setting
Setting value
|
content
|
0
|
0~+10v input (10 bit input )
|
1
|
0~+_10v input (when the voltage is minus ,it will be the operation command which has opposite operation to the operation of the given command )
|
2
|
4~20ma input
|
When used as input voltage terminal ( setting : 0 or 1 , please cut off the over line on the control plate ( if not the resistor will be burned ) . when voltage input terminal and current input terminal input frequency command simultaneously their summation will be the ultimate command value , in the occasion where voltage terminal and current terminal are used in turn , please set one of the multi function input ( H1_01 ~06 ) to be 1f and this multi function input 1S in off status , the current terminal (14) ,s command will be effective as long as the command from the voltage terminal ( 13 ) is on , when it is Et as 1 ( 0~ +_ 10 volt input ) it is necessary that H3_01 is 1 too (0~+_ 10 volt input )
Setting value
|
function
|
The content of each function at 100% input
|
Control methods
|
||||||
v/f
|
v/f
with pg
|
Open loop vector
|
Flux vector
|
||||||
0
|
H3 – 05 , auxiliary frequency command
|
Max , output frequency
|
0
|
0
|
0
|
0
|
|||
H3 – 09 , it cannot be set to be ,0,
|
|||||||||
1
|
Frequency gain
|
The value of frequency command ( voltage)
|
0
|
0
|
0
|
0
|
|||
2
|
Frequency off set (zero limit when operation direction changes )
|
Maximum output frequency (added to h3 – 03 )
|
0
|
0
|
0
|
0
|
|||
4
|
Output voltage off set
|
Motor rated voltage (E1-05)
|
0
|
0
|
x
|
x
|
|||
5
|
Time gain of acceleration/ deceleration (reduction ratio)
|
The set acceleration time (C1- o1~o8)
|
0
|
0
|
0
|
0
|
|||
6
|
DC braking (DB)current
|
Inverter rated current
|
0
|
0
|
0
|
x
|
|||
7
|
Over torque detection level
|
Motor rated torque
|
0
|
0
|
0
|
0
|
|||
8
|
Stall prevention level in operation
|
Inverter rated current
|
0
|
0
|
x
|
x
|
|||
9
|
Output frequency lower limit level
|
Max output frequency
|
0
|
0
|
0
|
0
|
|||
A
|
Prohibited frequency setting
|
Max output frequency
|
0
|
0
|
0
|
0
|
|||
B
|
PID feed back
|
Max output frequency
|
0
|
0
|
0
|
0
|
|||
C
|
PID target value
|
Max output frequency
|
0
|
0
|
0
|
0
|
|||
D
|
Frequency off set
Note: it is cannot be set simultaneously (opeo7)
|
Max output frequency (plus H3 – o3)
|
0
|
0
|
0
|
0
|
|||
10
|
Forward side torque limit
|
Motor rated torque
|
x
|
x
|
0
|
0
|
|||
11
|
Reverse operation side torque limit
|
Motor rated torque
|
x
|
x
|
0
|
0
|
|||
12
|
Torque limit in regeneration status
|
Motor rated torque
|
x
|
x
|
0
|
0
|
|||
13
|
Torque command/torque limit when speed controls
|
Motor rated torque
|
x
|
x
|
x
|
0
|
|||
14
|
Torque compensation
|
Motor rated torque
|
x
|
x
|
x
|
0
|
|||
15
|
For / rev two sides torque limit
|
Motor rated torque
|
x
|
x
|
x
|
0
|
|||
1f
|
H3 – 05 , analog input will not be used
|
Max output frequency
|
0
|
0
|
0
|
0
|
|||
Frequency command (please find function chart for details )
|
|||||||||