440 VOLT INVERTER,S (H3-01,11,12) CONSTANT FUNCTIONS

NO Name                         Description Setting range Factory setting Bias (terminal 14) The command value of each function when 0 v (4 ma)is input , the unit is % -100~ +100 0.0 H3-11 Note : as the adjustment constant of analog input it is classified into 3 types gain deviation ( to be set individually for … Read more

solar max inverter dc to ac

SOLAR MAX DC TO AC SOLAR INVERTER,S INSTALLATION AND HOW TO 24 DC VOLT WIRING NOTE: before installation please inspect the unit  be sure that nothing inside the package is damaged. MOUNTING THE UNIT . The unit only can be mounted vertically to a wall surface. please follow below steps, 1. turn off the unit … Read more

440 volt inverter terminals table

440 VOLT INVERTER,S TERMINALS TABLE No Name Description Setting range Factory setting Change During Option Control methods v/f v/f with pg Open loop vector Flux vector H4-03 Bias (terminal 21) To set the voltage level deviation of multi function analog value output 1 and make the output characteristic to be parallel to the value of … Read more

440 volt inverter analog signal level setting table

  No Name description Setting range Factory setting Change during operation Control methods v/f v/f with pg Open loop vector Flux vector H4-07 Analog output signal level selection The set signal output level of multi function analog value 1.2 (terminal 21,23)0:0~+10v 1:0~+_10v output note of setting : this signal level setting is suitable for multi … Read more

440 volt inverter motor protection table

440 VOLT WINNER INVERTER,S MOTOR PROTECTION TABLE No Name                                                    Description Setting range Factory setting Change during operation Control methods v/f v/f with pg Open loop vector Flux vector L1-01 Motor protection selection Sets whether the motor overload function is enabled or disabled at electric thermal overload relay 0: disabled 1:enabled Note : this setting … Read more

power inverter safety instructions

Safety instructions Alert: This chapter includes important protection and working instructions. Check and protect this manual for the maintenance of the function. 1. Before using the unit, studying all the instructions and precautions on the manual batteries and all appropriate section. 2. Carefully – To restrict the risk of injury, completely positioned in a position … Read more

inverter

  inverter,s stall functions inverter stall prevention selection during running. inverter stall prevention function selection during operation. 0 : non effective . 1 : effective deceleration time 1. 2 : effective deceleration time 2. how to make inverter when inverter setting 1 or 2 enabled is selected deceleration is started if the current of the … Read more

inverter torque system

torque detection selection 1. to set the torque detection function 0:overtorque detection disabled.1:detection during speed gree only/ operation continuos after detection (minor fault) 2:detection during run /operation continuous after detection (minor fault) 3:etection during speed only/inverter output is shut off after detection(fault) 4:detection during run/inverter output is shut off after detection (fault) torque detection level … Read more

inverter,s speed protection

forward torque limit set the torque limit values as a percentage of the motor rated torque.four indevidual regions can be set. reverse torque limit note: torque limits can be set seperately for the 4 ways that torque can be applied: forward torque,reverse torque,forwards generative torque,and reverse generative torque. forward regenerative torque limit show the relationship … Read more